1.
|
|
2.
|
Access to fulltext document - CERN library copies
|
3.
|
Measurements of the signal shape of a silicon strip detector with SCTA readout
/ Bartalini, P (LPHE, Lausanne) ; Buytaert, J (CERN) ; Collins, P (CERN) ; Dijkstra, H (CERN) ; Dormond, O (LPHE, Lausanne) ; Elsing, M (CERN) ; Fiedler, F (CERN) ; Frei, R (LPHE, Lausanne) ; Ketel, T (Vrije U., Amsterdam) ; Klous, S (Vrije U., Amsterdam) et al.
Data of a beam test in Autumn 1999 have been analysed to determine the pulse shape of the signal as read out by an SCTA chip from a detector prototype for the LHCb Vertex Locator. The measurements have been performed at different bias voltages and distinguishing non-irradiated and irradiated regions on the detector. [...]
LHCb-2000-098.-
Geneva : CERN, 2000 - 21 p.
Access to fulltext document: PS.GZ; Fulltext: PDF;
|
|
4.
|
Performance of a wide pitch n-on-n silicon detector with floating strips
/ Charles, M J (Oxford U.) ; Collins, P (CERN) ; Dijkstra, H (CERN) ; Dormond, O (LPHE, Lausanne) ; Ferro-Luzzi, M (CERN) ; Frei, R (LPHE, Lausanne) ; Gagliardi, G (LPHE, Lausanne) ; Kappert, L (NIKHEF, Amsterdam) ; Ketel, T (NIKHEF, Amsterdam) ; Klous, S (NIKHEF, Amsterdam) et al.
First measurements of charge sharing and collection for a 95 micron pitch n-on-n silicon sensor with floating strips are presented. These measurements were made with an analogue front-end sampling at 40 MHz. [...]
LHCb-2002-039.-
Geneva : CERN, 2002 - 22 p.
Access to fulltext document: PS.GZ; Fulltext: PDF;
|
|
5.
|
Performance of an irradiated n-on-n Hamamatsu prototype VELO detector
/ Bowcock, T J V (Liverpool U.) ; Buytaert, J (CERN) ; Casse, G (Liverpool U.) ; Charles, M J (Oxford U.) ; Dijkstra, H, (CERN) ; Collins, P (CERN) ; Dormond, O (LPHE, Lausanne) ; Ferro-Luzzi, M (CERN) ; Fiedler, F (CERN) ; Frei, R (LPHE, Lausanne) et al.
An n-on-n design LHCb PR-01 prototype VELO detector was irradiated and equipped with LHC speed electronics. This detector was successfully operated in a test-beam and its performance assessed. [...]
LHCb-2001-039.-
Geneva : CERN, 2001 - 23 p.
Access to fulltext document: PS.GZ; Fulltext: PDF;
|
|
6.
|
Study of resolution of VELO test-beam telescope
/ Wright, V (Liverpool U. ) ; Bartalini, P (LPHE, Lausanne ) ; Buytaert, J (CERN) ; Collins, P (CERN) ; Dijkstra, H (CERN) ; Dormond, O (LPHE, Lausanne ) ; Elsing, M (CERN) ; Frei, R (LPHE, Lausanne ) ; Ketel, T (Vrije U., Amsterdam ) ; Klaus, S (Vrije U., Amsterdam ) et al.
This note describes the systematic study made of the resolution of the LHCb VELO telescope used in the Autumn 99 test-beam. Measurements were made of the resolution for each region of both the LHCb {\it R} and $\Phi$ vertex detectors. [...]
LHCb-2000-103.-
Geneva : CERN, 2000 - 21 p.
Access to fulltext document: PS.GZ; Fulltext: PDF;
|
|
7.
|
LHCb flavour tagging performance
/ Calvi, M (Milan Bicocca U. ; INFN, Milan) ; Dormond, O (Lausanne U. ) ; Musy, M (Milan Bicocca U. ; INFN, Milan)
In CP violation measurements, the most accurate determination of the B flavour of neutral and charged B-mesons is necessary. In this note we summarize the tagging performances for the LHCb experiment, using different approaches and studying different decay channels..
LHCb-2003-115.-
Geneva : CERN, 2003 - 15 p.
Access to fulltext document: PS.GZ; Fulltext: PDF;
|
|
8.
|
VELO telescope resolution and efficiency measurements
/ Bartalini, P (LPHE, Lausanne) ; Buytaert, J (CERN) ; Charles, M J (Oxford U. ) ; Collins, P (CERN) ; Dijkstra, H (CERN) ; Dormond, O (LPHE, Lausanne) ; Elsing, M (CERN) ; Ferro-Luzzi, M (CERN) ; Fiedler, F (CERN) ; Frei, R (LPHE, Lausanne) et al.
The 1998 prototypes for the LHCb Vertex Locator were characterised in a beam test. The efficiency of the detectors was studied as a function of bias voltage. [...]
LHCb-2000-099.-
Geneva : CERN, 2000 - 44 p.
Access to fulltext document: PS.GZ; Fulltext: PDF;
|
|
9.
|
Charge collection efficiency and resolution of an irradiated double sided silicon microstrip detector operated at cryogenic temperatures
/ Bartalini, P ; Bowcock, T J V ; Buytaert, J ; Chabaud, V ; Collins, P ; Dijkstra, H ; Dormond, O ; Frei, R ; Parkes, C ; Ruf, T et al.
99-026 This paper presents results on the measurement of the cluster shapes, resolution and charge collection efficiency of a double sided silicon microstrip detector after irradiation with 24 GeV protons to a fluence of 3.5 x 10^14 p/cm2 and operated at cryogenic temperatures. An empirical model is presented which describes the expected cluster shapes as a function of depletion depth, and is shown to agree with the data. [...]
LHCb-99-026.-
Geneva : CERN, 1999
Fulltext: PDF;
|
|
10.
|
Performance of an irradiated p-on-n micro prototype VELO detector
/ Bowcock, T J V (Liverpool U. ) ; Buytaert, J (CERN) ; Casse, G (Liverpool U. ) ; Charles, M J (Oxford U. ) ; Dijkstra, H (CERN) ; Collins, P (CERN) ; Dormond, O (LPHE, Lausanne) ; Ferro-Luzzi, M (CERN) ; Fiedler, F (CERN) ; Frei, R (LPHE, Lausanne) et al.
A 200 micron thick p-on-n design LHCb PR-02 prototype VELO detector was irradiated and equipped with LHC-speed electronics. This detector was successfully operated in a test-beam and its performance assessed. [...]
LHCb-2001-040.-
Geneva : CERN, 2001 - 22 p.
Access to fulltext document: PDF;
|
|