1.
|
Numerical Calibration of the Bead-Pull Setup for Beam Coupling Impedance Evaluation
/ El Dali, Dalia Mahmoud Fouda (CERN) ; De Michele, Giovanni (ADAM, Geneva) ; Fanella, Stefano (ADAM, Geneva) ; Métral, Elias (CERN) ; Zannini, Carlo (CERN)
The bead-pull method is a commonly used electromagnetic field measurement technique exploited to tune a radiofrequency cavity to achieve design specifications. The frequency of a resonant cavity is perturbed by inserting a metallic or dielectric bead. [...]
2022 - 3 p.
- Published in : JACoW IPAC 2022 (2022) 607-609
Fulltext: PDF;
In : 13th International Particle Accelerator Conference (IPAC 2022), Bangkok, Thailand, 12 - 17 Jun 2022, pp.607-609
|
|
2.
|
Simulations and Measurements of the CCL Modules of the LIGHT Accelerator
/ Khan, Vasim (Unlisted, CH) ; De Michele, Giovanni (Unlisted, CH) ; Esposito, Marco (Unlisted, CH) ; Fanella, Stefano (Unlisted, CH) ; Gibson, Stephen (Unlisted, CH) ; Gradassi, Paolo (Unlisted, CH) ; Ivanisenko, Yevgeniy (Unlisted, CH) ; Mellace, Claudio (Unlisted, CH) ; Navarro Quirante, Jose Luis (Unlisted, CH) ; Zannini, Carlo (Unlisted, CH)
A 230 MeV proton LINAC system for medical applications is being developed and commissioned for the LIGHT (Linac Image Guided Hadron Therapy) project by AVO-ADAM. The LINAC system consists of a 750 MHz RFQ (Radio frequency quadrupole) for the low energy proton acceleration, 2998 MHz SCDTL (Side Coupled Drift Tube Linacs) for the medium energy and 2998 MHz CCL (Coupled Cavity Linacs) for the high energy. [...]
2018 - 3 p.
- Published in : 10.18429/JACoW-IPAC2018-MOPML015
Fulltext: PDF;
In : 9th International Particle Accelerator Conference, Vancouver, Canada, 29 Apr - 4 May 2018, pp.MOPML015
|
|
3.
|
Status of the Commissioning of the LIGHT Prototype
/ Degiovanni, Alberto (Unlisted, CH) ; Adam, Joel (Unlisted, CH) ; Aguilera Murciano, Debora (Unlisted, CH) ; Ballestrero, Sergio (Unlisted, CH) ; Benot-Morell, Alfonso (Unlisted, CH) ; Bonomi, Rossana (Unlisted, CH) ; Cabaleiro Magallanes, Francisco (Unlisted, CH) ; Caldara, Michele (Unlisted, CH) ; Cerv, Matevz (Unlisted, CH) ; D'Auria, Gerardo (Unlisted, CH ; Sincrotrone Trieste) et al.
The company A.D.A.M. (Application of Detectors and Accelerators to Medicine), a CERN spin-off, is working on the construction and testing of its first linear accelerator for medical application: LIGHT (Linac for Image-Guided Hadron Therapy). [...]
2018 - 4 p.
- Published in : 10.18429/JACoW-IPAC2018-MOPML014
Fulltext: PDF;
In : 9th International Particle Accelerator Conference, Vancouver, Canada, 29 Apr - 4 May 2018, pp.MOPML014
|
|
4.
|
Publication
|
5.
|
Beam-based measurements of long-range transverse wakefields in the Compact Linear Collider main-linac accelerating structure
/ Zha, Hao (CERN) ; Latina, Andrea (CERN) ; Grudiev, Alexej (CERN) ; De Michele, Giovanni (CERN ; PSI, Villigen ; LPHE, Lausanne) ; Solodko, Anastasiya (CERN) ; Wuensch, Walter (CERN) ; Schulte, Daniel (CERN) ; Adli, Erik (SLAC ; Oslo U.) ; Lipkowitz, Nate (SLAC) ; Yocky, Gerald S (SLAC)
The baseline design of CLIC (Compact Linear Collider) uses X-band accelerating structures for its main linacs. In order to maintain beam stability in multibunch operation, long-range transverse wakefields must be suppressed by 2 orders of magnitude between successive bunches, which are separated in time by 0.5 ns. [...]
2016 - 9 p.
- Published in : Phys. Rev. Accel. Beams 19 (2016) 011001
Fulltext: PDF;
|
|
6.
|
ebook
|
7.
|
Beam-Based Measurements of Long Range Transverse Wakefields in CLIC Main Linac Accelerating Structure
/ Zha, Hao (CERN) ; Adli, Erik (Oslo U.) ; De Michele, Giovanni (EPFL-ISIC, Lausanne ; PSI, Villigen) ; Grudiev, Alexej (CERN) ; Latina, Andrea (CERN) ; Lipkowitz, Nate (SLAC) ; Schulte, Daniel (CERN) ; Solodko, Anastasiya (CERN) ; Wuensch, Walter (CERN) ; Yocky, Gerald (SLAC)
The baseline design of CLIC (Compact Linear Collider) uses X-band accelerating structures in the main linac. Every accelerating structure cell has four waveguides, terminated with individual RF loads, to damp the unwanted long-range transverse wakefields, in order to maintain beam stability in multi-bunch operation. [...]
CERN-ACC-2015-264.-
2015 - 3 p.
- Published in : (2015) , pp. TUPTY056
Published version from JACoW: PDF; External link: JACOW
In : 6th International Particle Accelerator Conference, Richmond, VA, USA, 3 - 8 May 2015, pp.TUPTY056
|
|
8.
|
10.5075/epfl-thesis-6185
EPFL server - Full text
|
9.
|
Wake field monitors in a multi purpose X Band accelerating structure
/ Dehler, M (PSI, Villigen) ; Bettoni, S (PSI, Villigen) ; Beutner, B (PSI, Villigen) ; de Michele, G (PSI, Villigen ; Ecole Polytechnique, Lausanne ; CERN)
In a collaboration between CERN, PSI and Sincrotrone Trieste (ST), a series of four multipurpose X-band accelerating structures has been designed and fabricated. These feature integrated wake field monitors (WFMs), which are
used to measure the alignment (offset and tilt) between structure and beam. [...]
CERN-ACC-2014-0058.-
Geneva : CERN, 2013
Fulltext: PDF;
In : 2nd International Beam Instrumentation Conference, Oxford, UK, 16 - 19 Sep 2013, pp.WEBL3
|
|