Nothing Special   »   [go: up one dir, main page]

CERN Accelerating science

CERN Document Server 4 записей найдено  Поиск длился 0.53 секунд. 
1.
Beam test of a 10 gap MRC prototype as TOF detector / Li Cheng ; Chen Hong Fang ; Shao Ming ; Wang Xiao Lian ; Xu Zi Zong ; Zeng, Hui ; Ruan Li Juan ; Huang Sheng Li ; Sun Yong Jie ; Wu Jian et al.
A double superlayer MRPC with 2*5 gas gaps has been tested at the CERN-PS (T10) beam line. The prototype has a the sensitive area of 200 mm*63 mm with 2*6-readout pads, which are connected geometrically in series and electrically in parallel. [...]
2002 - Published in : High Energy Phys. Nucl. Phys.: 26 (2002) , no. 5, pp. 455-61
2.
A high time resolution multi-gap resistive plate chamber / Li Cheng ; Wu Jian ; Wang Xiao Lian ; Chen Hong Fang ; Xu Zi Zong ; Shao Ming ; Ye Shu Wei ; Ruan Li Juan ; Huang Sheng Li
Research on a single cell multi-gap resistive plate chamber (MRPC) was carried out for the time of flight detector (TOF) R&D; of the STAR experiment. The property of the single chamber was tested with the test beam facility T10 at CERN in Geneva. [...]
2002 - Published in : Nucl. Sci. Tech. 13 (2002) 6-10
3.
A prototype of the high time resolution MRPC / Li Cheng ; Wu Jian ; Chen Hong Fang ; Wang Xiao Lian ; Xu Zi Zong ; Wang Zhao Min ; Shao Ming ; Huang Sheng Li ; Ruan Li Juan
A prototype of single cell Multi-gap Resistive Plate Chamber (MRPC) has been made together with the setup of the test system. The property of the chamber has been tested with both the cosmic ray test system and the test beam facility T10 of CERN in Geneva. [...]
2001 - Published in : High Energy Phys. Nucl. Phys. (Beijing): 25 (2001) , no. 9, pp. 933-5
4.
Study on the light output nonuniformity of $PbWO_{4}$ crystal / Shao Ming ; Xu Tong ; Liu Ming Chang ; Wang Cong Rong ; Ruan Li Juan ; Chen Hong Fang ; Pan Xiao Hui ; Wang Cong Zhou
This paper presents measurements on the light output nonuniformity of a full size PbWO/sub 4/ crystal, which will be used in the electromagnetic calorimeter (ECAL) of the CMS detector. It makes use of a /sup 22/Na radioactive source and the coincidence method. [...]
2001 - Published in : High Energy Phys. Nucl. Phys. (Beijing): 25 (2001) , no. 6, pp. 555-60

Вы хотите получать уведомление о новых документах, соотетствующих этому запросу?
Установите персональное email оповещение или подпишитесь на RSS-канал.
не нашли то, что искали? Попробуйте поискать на других серверах
Chen Hong Fang в Amazon
Chen Hong Fang в CERN EDMS
Chen Hong Fang в CERN Intranet
Chen Hong Fang в CiteSeer
Chen Hong Fang в Google Books
Chen Hong Fang в Google Scholar
Chen Hong Fang в Google Web
Chen Hong Fang в IEC
Chen Hong Fang в IHS
Chen Hong Fang в INSPIRE
Chen Hong Fang в ISO
Chen Hong Fang в KISS Books/Journals
Chen Hong Fang в KISS Preprints
Chen Hong Fang в NEBIS
Chen Hong Fang в SLAC Library Catalog
Chen Hong Fang в Scirus