Nothing Special   »   [go: up one dir, main page]

CERN Accelerating science

Article
Title Characterisation of a medium-size-area high-rate multi-layer boron-coated GEM detector for thermal neutrons
Author(s) Cancelli, Stephanie (Milan Bicocca U. ; INFN, Milan Bicocca ; Bari U.) ; Muraro, Andrea (Bari U.) ; Murtas, Fabrizio (CERN ; Frascati) ; Cippo, Enrico Perelli (Bari U.) ; Altieri, Saverio (INFN, Pavia) ; Caruggi, Federico (Milan Bicocca U. ; INFN, Milan Bicocca) ; De Oliveira, Rui (CERN) ; Gorini, Giuseppe (Milan Bicocca U. ; INFN, Milan Bicocca ; Bari U.) ; Grosso, Giovanni (Bari U.) ; Lai, Chung-Chuan (ESS, Lund) ; Putignano, Oscar (Milan Bicocca U. ; INFN, Milan Bicocca) ; Tardocchi, Marco (INFN, Milan Bicocca ; Bari U.) ; Croci, Gabriele (Milan Bicocca U. ; INFN, Milan Bicocca ; Bari U.)
Publication 2024
Number of pages 7
In: Eur. Phys. J. Plus 139 (2024) 1026
DOI 10.1140/epjp/s13360-024-05790-z
Subject category Detectors and Experimental Techniques
Abstract During the last 10 years, the $^{3}$He crisis has brought to the development of new thermal neutron detection technologies and one of them is based on gas electron multiplier (GEM) principle. To detect neutrons, standard triple GEM detectors are usually coupled with a suitable converter, such as a $^{10}$B$_{4}$C, where neutrons are converted via the nuclear reaction $^{10}$B(n,$\alpha $)$^{7}$Li. The number of converted neutrons can be enhanced by increasing the amount of boron present in the detector. A recent work has shown the possibility to cover the GEM foils on both sides with a double layer of 10B4C, and the device has been realised using 3 small-area GEM foils (3x3 cm2) coupled with the TimePix electronic readout. A new triple GEM coupled with 3 boron-GEM (BGEM) foils with a larger active area of $10\times 10\text {cm}^2$ has now been produced and characterised. The new detector is equipped with a 16$\times $16 padded anode and with the GEMINI ASIC, a custom chip for GEM detectors. The device has been characterised with a thermal neutron beam provided at the Triga MARK II reactor in Pavia, to determine the working point, the detection efficiency, the counting rate and the imaging capability, showing similar performances to the previous smaller detector. In addition, the absolute detection efficiency respect to a reference $^{3}$He detector has been estimated.
Copyright/License © 2024 The Author(s) (License: exclusive licence to Società Italiana di Fisica and Springer-Verlag GmbH Germany, part of Springer Nature)

Corresponding record in: Inspire


 Запись создана 2024-12-10, последняя модификация 2024-12-10