002886428 001__ 2886428
002886428 003__ SzGeCERN
002886428 005__ 20240605102141.0
002886428 0248_ $$aoai:cds.cern.ch:2886428$$pcerncds:FULLTEXT$$pcerncds:CERN:FULLTEXT$$pINIS$$pcerncds:CERN
002886428 0247_ $$2DOI$$a10.22323/1.449.0578
002886428 037__ $$aCMS-CR-2023-228
002886428 035__ $$9INSPIRE$$a2751731
002886428 041__ $$aeng
002886428 100__ $$aJin, Weijie$$iINSPIRE-00801394$$jCCID-830342$$uZurich U.
002886428 245__ $$aPerformance and characterisation of the Phase-2 CMS Inner Tracker Endcap pixel detector
002886428 260__ $$c2023
002886428 269__ $$aGeneva$$bCERN$$c25 Oct 2023
002886428 300__ $$a6 p
002886428 520__ $$aThe High Luminosity Large Hadron Collider (HL-LHC) at CERN is expected to collide protons at 14 TeV center-of-mass energy and to reach the unprecedented peak instantaneous luminosity of 7.5 $\times 10^{34}$ cm$^{-2} $s$^{-1}$ with 200 collisions in average per bunch crossing. This will allow the ATLAS and CMS experiments to collect integrated luminosity up to 4000 fb$^{-1}$ each during the project lifetime. To cope with this extreme scenario, the CMS detector will be substantially upgraded before the HL-LHC phase, a plan known as the CMS Phase-2 upgrade. The entire CMS Inner Tracker (IT) detector will be replaced, and the new detector will feature increased radiation hardness, higher granularity, capability to handle higher data rates and longer trigger latency. The upgraded IT will be composed of a barrel part, TBPX, and small and large forward disks, TFPX and TEPX. The novel scheme of serial powering will be deployed to power the pixel modules, and new technologies will be used for a high bandwidth readout system. The TEPX detector has four large disks on each end, extending the tracking coverage up to $\lvert\eta\lvert < 4.0$. Each disk employs a thin PCB which carries the data and power from/to the modules. In this contribution, the design of the new TEPX detector will be presented, focusing on the disk characterization. The performance of the CMS Read-OUT Chip (CROC) quad modules, either digital or with planar sensors, will be discussed, with a focus on the comparison between the behaviour standalone or in a TEPX disk serial power chain, in terms of noise and threshold uniformity. The final design of the TEPX disk PCB is evaluated by testing the modules connected to the disk, in terms of data transmission quality compared to the standalone case.
002886428 595__ $$aCERN EDS
002886428 595__ $$aFor annual report
002886428 65017 $$2SzGeCERN$$aDetectors and Experimental Techniques
002886428 6531_ $$9CMS$$aGeneral
002886428 693__ $$aCERN LHC$$eCMS
002886428 690C_ $$aINTNOTE
002886428 690C_ $$aCERN
002886428 690C_ $$aPUBLCMS
002886428 690C_ $$aARTICLE
002886428 710__ $$5PH
002886428 710__ $$gCMS Collaboration
002886428 773__ $$c578$$pPoS$$vEPS-HEP2023$$y2024
002886428 8564_ $$82504676$$s8465358$$uhttp://cds.cern.ch/record/2886428/files/CR2023_228.pdf
002886428 916__ $$sn$$w20243
002886428 963__ $$aPUBLIC
002886428 962__ $$b2867206$$k578$$nhamburg20230820
002886428 980__ $$aINTNOTECMSPUBL
002886428 980__ $$aConferencePaper
002886428 980__ $$aARTICLE