Nothing Special   »   [go: up one dir, main page]

CERN Accelerating science

Article
Report number arXiv:2305.17762
Title Measurements of the Cherenkov effect in direct detection of charged particles with SiPMs
Author(s) Carnesecchi, F. (CERN) ; Sabiu, B. (Bologna U. ; INFN, Bologna) ; Strazzi, S. (Bologna U. ; INFN, Bologna) ; Vignola, G. (INFN, Bologna) ; Agrawal, N. (Bologna U. ; INFN, Bologna) ; Alici, A. (Bologna U. ; INFN, Bologna) ; Antonioli, P. (INFN, Bologna) ; Arcelli, S. (Bologna U. ; INFN, Bologna) ; Bellini, F. (Bologna U. ; INFN, Bologna) ; Cavazza, D. (INFN, Bologna) ; Cifarelli, L. (Bologna U. ; INFN, Bologna) ; Colocci, M. (Bologna U. ; INFN, Bologna) ; Durando, S. (Polytech. Turin) ; Ercolessi, F. (Bologna U. ; INFN, Bologna) ; Falchieri, D. (INFN, Bologna) ; Ficorella, A. (Fond. Bruno Kessler, Trento) ; Fraticelli, C. (Bologna U. ; INFN, Bologna) ; Garbini, M. (Enrico Fermi Ctr., Rome ; INFN, Bologna) ; Giacalone, M. (Bologna U. ; INFN, Bologna) ; Gola, A. (Fond. Bruno Kessler, Trento) ; Hatzifotiadou, D. (INFN, Bologna) ; Jacazio, N. (Bologna U. ; INFN, Bologna) ; Margotti, A. (INFN, Bologna) ; Malfattore, G. (Bologna U. ; INFN, Bologna) ; Nania, R. (INFN, Bologna) ; Noferini, F. (INFN, Bologna) ; Paternoster, G. (Fond. Bruno Kessler, Trento) ; Pinazza, O. (INFN, Bologna) ; Preghenella, R. (INFN, Bologna) ; Rath, R. (INFN, Bologna) ; Ricci, R. (U. Salerno (main)) ; Rignanese, L. (INFN, Bologna) ; Romanenko, G. (Bologna U. ; INFN, Bologna) ; Rubini, N. (Bologna U. ; INFN, Bologna) ; Scapparone, E. (INFN, Bologna) ; Scioli, G. (Bologna U. ; INFN, Bologna) ; Zichichi, A. (Bologna U. ; INFN, Bologna)
Publication 2023-09-05
Imprint 2023-05-28
In: Eur. Phys. J. Plus 138 (2023) 788
DOI 10.1140/epjp/s13360-023-04397-0
Subject category hep-ex ; Particle Physics - Experiment ; physics.ins-det ; Detectors and Experimental Techniques
Abstract In this paper, different Silicon PhotoMultiplier (SiPM) sensors have been tested with charged particles to characterize the Cherenkov light produced in the sensor protection layer. A careful position scan of the SiPM response has been performed with different prototypes, confirming the large number of firing cells and proving almost full efficiency, with the SiPM filling factor essentially negligible. This study also allowed us to study the time resolution of such devices as a function of the number of firing cells, reaching values below 20 ps. These measurements provide significant insight into the capabilities of SiPM sensors in direct detection of charged particles and their potential for several applications.
Copyright/License publication: © 2023-2024 The Author(s) (License: CC-BY-4.0)
preprint: (License: arXiv nonexclusive-distrib 1.0)



Corresponding record in: Inspire


 记录创建於2023-05-31,最後更新在2024-10-02


全文:
2305.17762 - Download fulltextPDF
document - Download fulltextPDF