002846099 001__ 2846099
002846099 003__ SzGeCERN
002846099 005__ 20230127164304.0
002846099 0248_ $$aoai:cds.cern.ch:2846099$$pcerncds:CERN
002846099 035__ $$9https://inspirehep.net/api/oai2d$$aoai:inspirehep.net:2614770$$d2023-01-12T16:20:25Z$$h2023-01-13T05:00:03Z$$mmarcxml
002846099 035__ $$9Inspire$$a2614770
002846099 041__ $$aeng
002846099 100__ $$aBaumann, Timm Felix$$uNorwegian U. Sci. Tech.$$uCERN$$vCERN - EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH, Geneva, Switzerland
002846099 245__ $$9IEEE$$aA quasi-offline condition monitoring method of DC-link capacitor banks in accelerator power converters
002846099 260__ $$c2022
002846099 300__ $$a12 p
002846099 520__ $$9IEEE$$aThis paper proposes a condition monitoring scheme for DC-link electrolytic capacitors used in regenerative medium power converters. The monitoring scheme is based on capacitor bank voltage measurements in quasi-offline mode. The aim of this work is to identify the voltage measurement precision and sampling requirements to enable a reproducible and reliable capacitance calculation. The proposed method is analysed theoretically and supported by simulation results and validated experimentally.
002846099 6531_ $$9author$$aCondition monitoring
002846099 6531_ $$9author$$aDegradation
002846099 6531_ $$9author$$aVoltage measurement
002846099 6531_ $$9author$$aCapacitors
002846099 6531_ $$9author$$aCapacitance
002846099 6531_ $$9author$$aHardware
002846099 6531_ $$9author$$aTime measurement
002846099 6531_ $$9author$$acondition monitoring
002846099 6531_ $$9author$$aelectrolytic capacitors
002846099 6531_ $$9author$$apower capacitors
002846099 6531_ $$9author$$apower convertors
002846099 6531_ $$9author$$avoltage measurement
002846099 6531_ $$9author$$aquasioffline condition monitoring method
002846099 6531_ $$9author$$aDC-link capacitor banks
002846099 6531_ $$9author$$aaccelerator power converters
002846099 6531_ $$9author$$acondition monitoring scheme
002846099 6531_ $$9author$$aDC-link electrolytic capacitors
002846099 6531_ $$9author$$aregenerative medium power converters
002846099 6531_ $$9author$$acapacitor bank voltage measurements
002846099 6531_ $$9author$$aquasioffline mode
002846099 6531_ $$9author$$avoltage measurement precision
002846099 6531_ $$9author$$asampling requirements
002846099 6531_ $$9author$$areproducible capacitance calculation
002846099 6531_ $$9author$$areliable capacitance calculation
002846099 690C_ $$aARTICLE
002846099 690C_ $$aCERN
002846099 700__ $$aPapastergiou, Konstantinos$$uCERN
002846099 700__ $$aGarcia, Raul Murillo$$uCERN
002846099 700__ $$aPeftitsis, Dimosthenis$$uNorwegian U. Sci. Tech.
002846099 773__ $$wC22-09-05.11$$y2022
002846099 8564_ $$uhttp://ieeexplore.ieee.org/document/9907429/
002846099 962__ $$b2846064$$nhannover20220905
002846099 960__ $$a13
002846099 980__ $$aARTICLE
002846099 980__ $$aConferencePaper