Title The Triple GEM Detector Control System for CMS forward muon spectrometer upgrade
Author(s) Ahmed, W (NCP, Islamabad) ; Abbaneo, D (CERN) ; Abbrescia, M (INFN, Bari ; Bari Polytechnic) ; Abdelalim, A A (British U. in Egypt) ; Akl, M Abi (Texas A&M; U. Qatar, Doha) ; Acosta, D (Florida U.) ; Ahmad, A (NCP, Islamabad) ; Ahmed, W (British U. in Egypt) ; Aleksandrov, A (Sofiya, Inst. Nucl. Res.) ; Aly, R (British U. in Egypt) ; Altieri, P (INFN, Bari ; Bari Polytechnic) ; Asawatangtrakuldee, C (Peking U.) ; Aspell, P (CERN) ; Assran, Y (Cairo, Acad. Sci. Res. Tech.) ; Awan, I (NCP, Islamabad) ; Bally, S (CERN) ; Ban, Y (Peking U.) ; Banerjee, S (Saha Inst.) ; Barashko, V (Florida U.) ; Barria, P (Brussels U.) ; Bencze, G (Wigner RCP, Budapest) ; Beni, N (Debrecen, Inst. Nucl. Res.) ; Benussi, L (Frascati) ; Bhopatkar, V (Florida Inst. Tech.) ; Bianco, S (Frascati) ; Bos, J (CERN) ; Bouhali, O (Texas A&M; U. Qatar, Doha) ; Holme, O (CERN) ; Braghieri, A (INFN, Pavia ; Pavia U.) ; Braibant, S (INFN, Bologna ; U. Bologna, DIFA) ; Buontempo, S (INFN, Naples) ; Khan, S A (NCP, Islamabad) ; Calabria, C (INFN, Bari ; Bari Polytechnic) ; Caponero, M (Frascati) ; Caputo, C (INFN, Bari ; Bari Polytechnic) ; Cassese, F (INFN, Naples) ; Castaneda, A (Texas A&M; U. Qatar, Doha) ; Cauwenbergh, S (Gent U.) ; Cavallo, F R (INFN, Bologna ; U. Bologna, DIFA) ; Celik, A (Texas A-M) ; Choi, M (Seoul U.) ; Choi, S (Korea U.) ; Christiansen, J (CERN) ; Cimmino, A (Gent U.) ; Colafranceschi, S (CERN) ; Colaleo, A (INFN, Bari ; Bari Polytechnic) ; Conde Garcia, A (CERN) ; Czellar, S (Debrecen, Inst. Nucl. Res.) ; Dabrowski, M M (CERN) ; De Lentdecker, G (Brussels U.) ; De Oliveira, R (CERN) ; de Robertis, G (INFN, Bari ; Bari Polytechnic) ; Dildick, S (Gent U.) ; Dorney, B (CERN) ; Elmetenawee, W (British U. in Egypt) ; Endroczi, G (Wigner RCP, Budapest) ; Errico, F (INFN, Bari ; Bari Polytechnic) ; Fenyvesi, A (Debrecen, Inst. Nucl. Res.) ; Ferry, S (CERN) ; Furic, I (Florida U.) ; Giacomelli, P (INFN, Bologna ; U. Bologna, DIFA) ; Gilmore, J (Texas A-M) ; Golovtsov, V (St. Petersburg, INP) ; Guiducci, L (INFN, Bologna ; U. Bologna, DIFA) ; Guilloux, F (IRFU, Saclay) ; Gutierrez, A (Wayne State U.) ; Hadjiiska, R M (Sofiya, Inst. Nucl. Res.) ; Hassan, A (British U. in Egypt) ; Hauser, J (UCLA) ; Hoepfner, K (Aachen, Tech. Hochsch.) ; Hohlmann, M (Florida Inst. Tech.) ; Hoorani, H (NCP, Islamabad) ; Shah, A H (Delhi U.) ; Iaydjiev, P (Sofiya, Inst. Nucl. Res.) ; Jeng, Y G (Seoul U.) ; Kamon, T (Texas A-M) ; Karchin, P (Wayne State U.) ; Korytov, A (Florida U.) ; Krutelyov, S (Texas A-M) ; Kumar, A (Delhi U.) ; Kim, H (Seoul U.) ; Lenzi, T (Brussels U.) ; Litov, L (Sofiya U.) ; Loddo, F (INFN, Bari ; Bari Polytechnic) ; Madorsky, A (Florida U.) ; Maerschalk, T (Brussels U.) ; Maggi, M (INFN, Bari ; Bari Polytechnic) ; Magnani, A (INFN, Pavia ; Pavia U.) ; Mal, P K (IcfaiTech, Bhubaneswar) ; Mandal, K (IcfaiTech, Bhubaneswar) ; Marchioro, A (CERN) ; Marinov, A (CERN) ; Majumdar, N (Saha Inst.) ; Merlin, J A (CERN) ; Mitselmakher, G (Florida U.) ; Mohanty, A K (Bhabha Atomic Res. Ctr.) ; Mohapatra, A (Florida Inst. Tech.) ; Molnar, J (Debrecen, Inst. Nucl. Res.) ; Muhammad, S (NCP, Islamabad) ; Mukhopadhyay, S (Saha Inst.) ; Naimuddin, M (Delhi U.) ; Nuzzo, S (INFN, Bari ; Bari Polytechnic) ; Oliveri, E (CERN) ; Pant, L M (Bhabha Atomic Res. Ctr.) ; Paolucci, P (INFN, Naples) ; Park, I (Seoul U.) ; Passeggio, G (INFN, Naples) ; Pavlov, B (Sofiya U.) ; Philipps, B (Aachen, Tech. Hochsch.) ; Piccolo, D (Frascati) ; Postema, H (CERN) ; Puig Baranac, A (CERN) ; Radi, A (Cairo, Acad. Sci. Res. Tech.) ; Radogna, R (INFN, Bari ; Bari Polytechnic) ; Raffone, G (Frascati) ; Ranieri, A (INFN, Bari ; Bari Polytechnic) ; Rashevski, G (Sofiya, Inst. Nucl. Res.) ; Riccardi, C (INFN, Pavia ; Pavia U.) ; Rodozov, M (Sofiya, Inst. Nucl. Res.) ; Rodrigues, A (CERN) ; Ropelewski, L (CERN) ; RoyChowdhury, S (Saha Inst.) ; Ryu, G (Seoul U.) ; Ryu, M S (Seoul U.) ; Safonov, A (Texas A-M) ; Salva, S (Gent U.) ; Saviano, G (Frascati) ; Sharma, A (CERN) ; Sharma, R (Delhi U.) ; Shopova, M (Sofiya, Inst. Nucl. Res.) ; Sturdy, J (Wayne State U.) ; Sultanov, G (Sofiya, Inst. Nucl. Res.) ; Swain, S K (IcfaiTech, Bhubaneswar) ; Szillasi, Z (Debrecen, Inst. Nucl. Res.) ; Talvitie, J (Lappeenranta U. Tech.) ; Tatarinov, A (Texas A-M) ; Tuuva, T (Lappeenranta U. Tech.) ; Tytgat, M (Gent U.) ; Vai, I (INFN, Pavia ; Pavia U.) ; Van Stenis, M (CERN) ; Venditti, R (INFN, Bari ; Bari Polytechnic) ; Verhagen, E (Brussels U.) ; Verwilligen, P (INFN, Bari ; Bari Polytechnic) ; Vitulo, P (INFN, Pavia ; Pavia U.) ; Volkov, S (St. Petersburg, INP) ; Vorobyev, A (St. Petersburg, INP) ; Wang, D (Peking U.) ; Wang, M (Peking U.) ; Yang, U (Seoul Natl. U. (main)) ; Yang, Y (Brussels U.) ; Yonamine, R (Brussels U.) ; Zaganidis, N (Gent U.) ; Zenoni, F (Brussels U.) ; Zhang, A (Florida Inst. Tech.)
Collaboration CMS muon
Publication 2017
Number of pages 15
In: JINST 12 (2017) P02003
DOI 10.1088/1748-0221/12/02/P02003
Subject category Detectors and Experimental Techniques
Accelerator/Facility, Experiment CERN LHC ; CMS
Abstract The CMS experiment at LHC will upgrade its forward muon spectrometer by incorporating Triple-GEM detectors. This upgrade referred to as GEM Endcap (GE1/1), consists of adding two back-to-back Triple-GEM detectors in front of the existing Cathode Strip Chambers (CSC) in the innermost ring of the endcap muon spectrometer. Before the full installation of 144 detectors in 2019–2020, CMS will first install ten single chamber prototypes during the early 2017. This pre-installation is referred as the slice test. These ten detectors will be read-out by VFAT2 chips [1]. On-detector there is also a FPGA mezzanine card which sends VFAT2 data optically to the μTCA back-end electronics. The correct and safe operation of the GEM system requires a sophisticated and powerful online Detector Control System, able to monitor and control many heterogeneous hardware devices. The DCS system developed for the slice test has been tested with CMS Triple-GEM detectors in the laboratory. In this paper we describe the newly developed DCS system and present the first results obtained in the GEM assembly and quality assurance laboratory.
Copyright/License publication: (License: cc-by)

Corresponding record in: Inspire


 Notice créée le 2017-06-16, modifiée le 2019-10-15