Nothing Special   »   [go: up one dir, main page]

CERN Accelerating science

Published Articles
Title Utilizing the N beam position monitor method for turn-by-turn optics measurements
Author(s) Langner, A (CERN ; Hamburg U.) ; Benedetti, G (ATIPIC) ; Carlà, M (ATIPIC) ; Iriso, U (ATIPIC) ; Martí, Z (ATIPIC) ; de Portugal, J Coello (CERN) ; Tomás, R (CERN)
Publication 2016
Number of pages 6
In: Phys. Rev. Accel. Beams 19 (2016) 092803
DOI 10.1103/PhysRevAccelBeams.19.092803
Subject category Accelerators and Storage Rings
Abstract The N beam position monitor method (N-BPM) which was recently developed for the LHC has significantly improved the precision of optics measurements that are based on BPM turn-by-turn data. The main improvement is due to the consideration of correlations for statistical and systematic error sources, as well as increasing the amount of BPM combinations which are used to derive the β-function at one location. We present how this technique can be applied at light sources like ALBA, and compare the results with other methods.
Copyright/License CC-BY-3.0
Publication: © 2016-2024 authors

Corresponding record in: Inspire


 记录创建於2017-04-26,最後更新在2021-05-03


全文:
Download fulltext
PDF