Nothing Special   »   [go: up one dir, main page]

CERN Accelerating science

Published Articles
Title The RICH detector of the NA62 experiment at CERN
Author(s) Aisa, D (Perugia U. ; INFN, Perugia) ; Anzivino, G (Perugia U. ; INFN, Perugia) ; Bizzetti, A (Modena U. ; INFN, Florence) ; Bucci, F (INFN, Florence) ; Campeggi, C (Perugia U. ; INFN, Perugia) ; Carassiti, V (INFN, Ferrara) ; Cassese, A (INFN, Florence ; Florence U.) ; Cenci, P (INFN, Perugia) ; Ciaranfi, R (INFN, Florence) ; Duk, V (INFN, Perugia) ; Farnesini, L (INFN, Perugia) ; Fry, J R (Liverpool U. ; CERN) ; Iacopini, E (INFN, Florence ; Florence U.) ; Lami, S (INFN, Pisa) ; Lenti, M (INFN, Florence) ; Maletta, F (INFN, Florence) ; Pepe, M (INFN, Perugia) ; Piandani, R (INFN, Pisa) ; Piccini, M (INFN, Perugia) ; Piluso, A (Perugia U. ; INFN, Perugia) ; Santoni, C (Perugia U. ; INFN, Perugia) ; Schneider, T (CERN) ; Sergi, A (Birmingham U.) ; Wertelaers, P (CERN)
Publication 2014
Number of pages 4
In: Nucl. Instrum. Methods Phys. Res., A 766 (2014) 1-4
In: 8th International Workshop on Ring Imaging Cherenkov Detectors, Hayama, Kanagawa, Japan, 2 - 6 Dec 2013, pp.1-4
DOI 10.1016/j.nima.2014.06.089
Subject category Detectors and Experimental Techniques
Accelerator/Facility, Experiment CERN SPS ; NA62
Abstract The NA62 experiment at CERN aims to measure the branching ratio of the ultra-rare charged kaon decay K+→π+νν¯ with a 10% accuracy and with a background contamination at the 10% level. Since the branching ratio of this decay is O (10 −10 ), to fulfill such request one of the main backgrounds, the decay K+→μ+ν (BR  63% ), must be suppressed by a rejection factor of 4×10 −13 (assuming 10% signal acceptance). This can be partially accomplished using a combination of kinematical cuts (8×10 −6 ) and the different power of penetration through matter of pions and muons (10 −5 ). A further 5×10 −3 suppression factor will be provided by a RICH detector, in a momentum range between 15 and 35 GeV/c. The details of the RICH project as well as the results from test runs performed on a RICH prototype of the same length of the final detector will be presented. The current status of the construction and the description of the final readout and trigger electronics will also be reviewed.
Copyright/License publication: © 2014-2024 CERN (License: CC-BY-4.0)

Corresponding record in: Inspire


 Element opprettet 2015-05-08, sist endret 2022-08-10


Elsevier Open Access article:
Last ned fulltekst
PDF