Article
Report number arXiv:0902.1116 ; FERMILAB-PUB-09-050-E
Title Comparisons of the MINOS Near and Far Detector Readout Systems at a Test Beam
Related titleComparisons of the MINOS Near and Far Detector Readout Systems at a Test Beam
Author(s)

Cabrera, A. (Oxford U.) ; Adamson, P. (University Coll. London) ; Barker, M. (Oxford U.) ; Belias, A. (Rutherford) ; Boyd, S. (Pittsburgh U.) ; Crone, G. (University Coll. London) ; Drake, G. (Argonne) ; Falk, E. (Sussex U.) ; Harris, P.G. (Sussex U.) ; Hartnell, J. (Oxford U.) ; Jenner, L. (University Coll. London) ; Kordosky, M. (Texas U.) ; Lang, K. (Texas U.) ; Litchfield, R.P. (Oxford U.) ; de Michael, D. (Caltech) ; Miyagawa, P.S. (Oxford U.) ; Morse, R. (Sussex U.) ; Murgia, Simona (Stanford U., Phys. Dept.) ; Nichol, R. (University Coll. London) ; Nicholls, T. (Rutherford) ; Pearce, G.F. (Rutherford) ; Petyt, D. (Minnesota U.) ; Reyna, D. (Argonne) ; Saakyan, R. (University Coll. London) ; Shanahan, P. (Fermilab) ; Smith, C. (University Coll. London) ; Symes, P. (Sussex U.) ; Tagg, N. (Oxford U.) ; Thomas, J. (University Coll. London) ; Vahle, P. (Texas U.) ; Weber, A. (Oxford U.)

Publication 2009
Imprint 09 Feb 2009
Number of pages 23
Note Comments: Preprint submitted to Elsevier. 23 pages, 8 figures
25 pages, 8 figures
In: Nucl. Instrum. Methods Phys. Res., A 609 (2009) 106-113
DOI 10.1016/j.nima.2009.07.016
Subject category physics.ins-det
Accelerator/Facility, Experiment CERN PS
MINOS
CERN PS
Test beam T7
Abstract MINOS is a long baseline neutrino oscillation experiment that uses two detectors separated by 734 km. The readout systems used for the two detectors are different and have to be independently calibrated. To verify and make a direct comparison of the calibrated response of the two readout systems, test beam data were acquired using a smaller calibration detector. This detector was simultaneously instrumented with both readout systems and exposed to the CERN PS T7 test beam. Differences in the calibrated response of the two systems are shown to arise from differences in response non-linearity, photomultiplier crosstalk, and threshold effects at the few percent level. These differences are reproduced by the Monte Carlo (MC) simulation to better than 1% and a scheme that corrects for these differences by calibrating the MC to match the data in each detector separately is presented. The overall difference in calorimetric response between the two readout systems is shown to be consistent with zero to a precision of 1.3% in data and 0.3% in MC with no significant energy dependence.



Corresponding record in: Inspire