Abstract
| In order to improve luminosity tuning and maintenance for the CLEO-c high energy physics (HEP) program at the Cornell Electron Storage Ring (CESR), a luminosity monitor using photons from radiative Bhabha events has been installed in the CESR ring. Over 10 meters of CESR vacuum chambers near the interaction region were modified to accommodate this new device. The vacuum modifications were designed to meet two criteria. First, the new vacuum chambers had to provide sufficient horizontal and vertical aperture for photons originating from the IP over a wide range of colliding beam conditions. Secondly, the new vacuum chambers required adequate safety margins for operation at beam energies up to 5.3 GeV for Cornell High Energy Synchrotron Source running. In order to be certain that the vacuum modifications would not give rise to any localized pressure bumps, a detailed calculation of the expected vacuum pressure distribution due to synchrotron radiation flux was carried out. Careful design and planning enabled a successful installation and resumption of CESR operations in record time. |