Home > Non-compensation of an Electromagnetic Compartment of a Combined Calorimeter |
Internal Note | |
Report number | hep-ex/9911033 ; JINR-E1-99-303 ; ATL-TILECAL-99-021 ; JINR-E1-99-303 |
Title | Non-compensation of an Electromagnetic Compartment of a Combined Calorimeter |
Author(s) | Kulchitsky, Y.A. (Minsk, Inst. Phys. ; Dubna, JINR) ; Kuzmin, M.V. (Minsk, Inst. Phys. ; Dubna, JINR) ; Vinogradov, V.B. (Dubna, JINR) |
Publication | 1999 |
Imprint | 1999 |
Number of pages | 17 |
Subject category | Detectors and Experimental Techniques |
Accelerator/Facility, Experiment | CERN SPS |
Keywords | Combined calorimeter |
Abstract | The method of extraction of the $e/h$ ratio, the degree of non-compensation, of the electromagnetic compartment of the combined calorimeter is suggested. The $e/h$ ratio of $1.74\pm0.04$ has been determined on the basis of the 1996 combined calorimeter test beam data. This value agrees with the prediction that $e/h > 1.7$ for this electromagnetic calorimeter. |
Other source | Inspire |
Copyright/License | Preprint: (License: CC-BY-4.0) |
Submitted by | Iouri.Koultchitski@cern.ch ; kulcicki@nusun.jinr.ru |